English

Fira Granvia have been appointed as the official electrical contractor for the show.  

If you have a space only stand, All electrical requirements, including switchboards, must be arranged through the Fira Store via the link below. Please note that all powerboxes will be protected with a 30 mA RCCB and will include power supply for the last two build-up days and all show days. If you require any something different or power supply for other days, these can be requested at labelexpo@firabarcelona.com.

If you have a Shell Scheme Premium stand, you will automatically receive the following: 

Package Stand: 

  • 3 x spotlights 
  • 1 x 500w socket 

(nb: quantity varies depending on stand size) 

Any additional sockets or lights must be ordered and arranged through GES the shell scheme contractor for the show: https://ordering.ges.com/000406040 

 

Electrical regulations 
The official supplier of electricity is Fira de Barcelona. It is mandatory to order power boxes via the Fira Store for space only stands.  

The venue is solely responsible for installing electrical mains on stands and ensuring all connections are safe before use. Exhibitors and contractors may bring their own extension leads, adaptors, and power tools. However, all electrical equipment must be tested by a qualified electrician, including insulation and earth bonding checks, and display clear inspection labels.
PLEASE NOTE: if you have shell scheme stand additional electrical orders for sockets must be placed through GES.

Power tools should be battery-operated or use 230 volts / 50hz or lower. Event organizers reserve the right to inspect, test, and remove any electrical equipment that is defective or lacks proper inspection documentation. 

Power will be distributed by the venue from the floor ducts. 

If the stand installation does not meet the set requirements, it cannot be connected to the power grid within the venue. These requirements must be complied before power can be supplied to your stand. Electrical (switching) panels must not be accessible to visitors. The installation of an R CCB (residual-current circuit breaker) for a nominal fault current of 0.03A is obligatory for the electrical infrastructure. 

In case of a raised floor, the electricity distribution point must be accessible. 

Earth leakage circuit breakers must have classification A (AC are not permitted). 

For safety reasons, connections to existing utilities may only per formed by the venue or its authorized service partners. 


Service chests 
All service chests must be accessible at all times. Service chests with no live services coming from them must also remain accessible in case of emergency. 

If your stand contains multiple service chests , you are free to decide which ones you want to use. If you order your electrical installation through ServiFira, should include a floorplan marking the service chest you want to use. 

If your service chest is shared with another exhibitor(s), it must be accessible for your neighboring exhibitor(s) at any time. Therefore, shutting off power or placing a lockable cover on the service chest is strictly prohibited.

Where there is a live service chest, the carpet should have a cut area of 100cm or, in the case of a raised floor, an access hatch should be incorporated into the design. With a hatch, a platform of 5cm is recommended for electrical cables only, and 10cm if a water connection is planned for any of the neighbouring stands. 

Please note that it could be the case that live services are being sourced from the service chest on your stand to yourself and neighboring exhibitors. If you are unsure whether you have a service chest on your stand, please contact ServiFira.  

For technical details of electrical installations, please read Fira de Barcelona Technical Regulations

 

Servifira electrical package: 
Servifira provides a comprehensive electrical package for exhibitors. This includes full installation, a power box with 10m cabling, choice of daily or continuous power supply, compliance certification, and incident assistance. The package covers all necessary electricity taxes and ensures adherence to local regulations, simplifying your setup process.  
 

Pricing and ordering: 
Electricity is charged in euros per kilowatt per day. Order power for build-up, show, and dismantling days as needed. Special installations may incur extra charges, which ServiFira will communicate. Payment must be received before installation approval to ensure power at your stand. 
 

High power requirements: 
Stands requiring from 50 kW need a Technical Design Project approved by a local collegiate engineer (fee applies). Consult Fira de Barcelona Technical Regulations, Chapter 6.2, for details or contact Servifira for assistance. 
 

Connection options: 
Choose between daytime (12 hours) or permanent (24 hours) connections. Permanent connections are recommended for stands with refrigeration units or equipment needing constant power. For any questions or to discuss your specific electrical needs, please contact labelexpo@firabarcelona.com